Solenoid Valve, Liquid Line Solenoid & Defrost Solenoid Valve Selection

Solenoid valve is an on-off control component; cuts off or opens refrigerant flow according to electric signal from controller. Liquid line solenoid valve: before expansion valve; closes automatically when thermostat reaches set temperature, stops liquid supply. Without liquid solenoid valve, refrigerant will continue migrating to evaporator during compressor off period, causing flood-back at next startup. Hot gas defrost solenoid valve: controls high pressure hot gas entering air cooler coil for defrost cycle. Solenoid coil has different voltage options: 24VAC, 220VAC, 380VAC, must match local export power standard. Xiteliduo rack system uses pilot operated solenoid valve for large flow, direct acting type for small capacity circuit. Direct acting: small flow, low pressure difference; pilot operated: big flow, suitable for large refrigeration circuit. Solenoid valve must be installed with flow arrow direction; debris stuck on valve seat causes internal leakage. Valve seat leakage symptom: compressor still pumps down slowly after shutdown, continuous frost on valve outlet side. Refrigeration maintenance & repair judge solenoid leakage when cooling keeps running after room temperature reaches target.

FAQ

  1. What is the function of liquid line solenoid valve? Cut liquid supply when thermostat satisfies set temperature.
  2. What risk without liquid solenoid valve? Refrigerant migration and liquid flood-back on startup.
  3. What solenoid controls hot gas defrost? Defrost hot gas solenoid valve.
  4. What is the difference between direct acting and pilot solenoid? Direct acting for small flow; pilot operated for large flow.
  5. What is the common fault of solenoid valve? Foreign matter stuck on seat causing internal leakage.
  6. What symptom of solenoid seat leakage? Outlet side keeps frosting after closing signal.
  7. What voltage options for export solenoid coil? 24VAC, 220VAC, 380VAC.
  8. Does solenoid valve need to follow flow arrow? Yes.
url: https://tl.xtldcool.com/news/848.html

Kumuha ng mga plano para sa pag-customize ng produkto online

Pakipunan ang mga kinakailangan sa kahon sa ibaba, at makukuha mo ito nang libre.

Consulting Hotline

+86-18157593311

Xiteliduo & Chuanli

Pabrika mula sa China ng R32 Semi-Hermetic Piston Compressor at Custom Turnkey Industrial Refrigeration System. Sariling binuo na compressor + kumpletong solusyon sa pagpapalamig, matatag na pagganap para sa tropikal at ultra-mababang temperatura sa mga kondisyon ng pagtatrabaho.

Ikonekta kami

Mga Teknikal na Serbisyo: +86-575-83665888;83068555

Compressor Hotline: +86-18157593311

Hotline para sa Electric Heating Tube: +86-13857577938

Email: helenliu1983xtld@gmail.com

Pabrika ng Electric Heating Tube: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City

Pabrika ng Compressor: Blg. 679, Dongguo Economic Development Zone, Lungsod ng Shengzhou, Lungsod ng Shaoxing

Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. Lahat ng Karapatan ay Nakalaan.